COULTER* LH 780 The advanced technologies of the LH 780 hematology series  deliver  uncompromising performance with a full complement of automated capabilities.

Fully automated “Random Access” hematology analyzer with white cells advanced differential, on-line reticulocytes, Body fluids and Nucleated RBC.

Complaint Order

Online Order

Complaint

Download Product Brochure FC-500 Flowcytometer.pdf Beckman Coulter lh780.jpg

WBC, RBC, Hgb, Hct, MCV, MCH, MCHC, RDW, Plt, Pct,

MPV, PDW, NE%, NE#, LY%, LY#, MO%, MO#, EO%, EO#,

BA%, BA#, RET%, RET#, MRV, IRF, HLS#, HLS%

NRBC (%versus 100 WBC)

Superior differential and Retic results using patented technologies such as 3D VCS, Intellikinetics, AccuGate and Accucount Software.

Over 8000 leucocytes analyzed in their near native state by  VCS Technology to report precise WBC differential results.

WBC: from 0.00 to 400.00 x 103 cells/µl with automatic Interference correction

Plt: from 0.00 to 3000 x 103 cells/µl

RBC: from 0.00 to 8.00 x 106 cells/µl

Hgb: from 0.0 to 25.0 g/dl

Ret#: from 0.0 to 0.750 x 106 cells/µl

RBC%: from 0 to 30%

More than 32,000 RBCs analyzed to report Retic results

Auto correction for WBC and RBC when WBC=> 140

Adjusted MCH, MCHC, HCT Retic # and HLR# using corrected RBC

Walk away automation system using Smart start and continuous sample loading on a Universal Tube Processing Module with ability to interrupt for Stat samples.

Positive sample ID with on-bard bar code reader.

Sample capacity: 144 tubes (12 cassettes of 12 tubes)

Sample volume: 300µl in automatic mode and 200µl in manual mode.

Throughput: 110/hr CBC only, 110/hr CBC + Diff, 50/hr CBC + Diff + Retic  

Triplicate counting, Pulse editing, extended counts and sweep flow technology for accurate and precise results.

Auto probe wipe (rinse/dry) for open vial samples.

Zero routine maintenance, automatic start and shutdown cycles.

Fax, Result Edit, Recalculate Data on Edit, Archiving on floppy, Auto Collation, Auto Verification and Support for any Windows NT-compatible Printer

Comprehensive flagging system for abnormal cell types and patterns, atypical and immature cells, laboratory definable quantitative abnormalities and High/Low range flags.

User definable normal ranges for different age and sex groups.

Customizable validation rules and delta check with previous historic data if any Decision rules include the use of the RDW-SD RUO parameters and RUO suspect messages

Computer Workstation (PN 2016939) running Windows 2000 software, TFT flat screen (PN 2016939) providing:

Storage of up to 20,000 numeric results, last 5000 stored with all graphics and last 500 stored with raw list mode data.

Unlimited QC data storage with unlimited data points/control file.

Extended QC Rules (Relibeak) On-board QC functions allowing automatic data intake from

Bar-coded disk-based controls directly into control files.

Provides XB (mean) batch analysis on patient CBC data, and Levy-Jennings plots for each parameters and Delta Check.

XMMoving Averages (user enabled) Bi-Directional Interface and remote service access by modem.

Advanced Bar Code Reader (ABCR)

Dimensions:  W: 102cm, D: 61cm, H:90cm

Weight       :  93 Kg

Specifications